Sw xtr 03: restore factory calibration
Basic example that restores the factory calibration of any parameter
Required Materials
- 1 Waspmote Plug & Sense! Smart Water Xtreme - 1 sensor for Smart Water Xtreme
Notes
- This example is only valid for Waspmote v15
Code
/*
----------- [Sw_xtr_03] - Restore factory calibration -----------
Explanation: Basic example that restores the factory calibration
of any parameter
Copyright (C) 2018 Libelium Comunicaciones Distribuidas S.L.
http://www.libelium.com
This program is free software: you can redistribute it and/or modify
it under the terms of the GNU General Public License as published by
the Free Software Foundation, either version 3 of the License, or
(at your option) any later version.
This program is distributed in the hope that it will be useful,
but WITHOUT ANY WARRANTY; without even the implied warranty of
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
GNU General Public License for more details.
You should have received a copy of the GNU General Public License
along with this program. If not, see .
Version: 3.0
Design: David Gascón
Implementation: J.Siscart, V.Boria
*/
#include
/*
SELECT THE RIGHT SOCKET FOR EACH SENSOR.
Possible sockets for this sensor are:
- XTR_SOCKET_E _________
|---------|
| A B C |
|_D__E__F_|
Refer to the technical guide for information about possible combinations.
www.libelium.com/downloads/documentation/smart_agriculture_xtreme_sensor_board.pdf
*/
//Uncomment the sensor that you want to read the serial number
Aqualabo_OPTOD mySensor(XTR_SOCKET_E);
//Aqualabo_PHEHT mySensor(XTR_SOCKET_E);
//Aqualabo_C4E mySensor(XTR_SOCKET_E);
//Aqualabo_NTU mySensor(XTR_SOCKET_E);
//Aqualabo_CTZN mySensor(XTR_SOCKET_E);
//Aqualabo_MES5 mySensor(XTR_SOCKET_E);
uint8_t response = 0;
void setup()
{
// 1.Turn ON the sensor
mySensor.ON();
// 2. Restores the sensor to factory calibration
//!*************************************************************
//! Name: restoreToFactoryCalibration(uint8_t parameter)
//!
//! Description: Restores the sensor to factory calibration
//!
//! Param: parameter
//! for OPTOD select from: TEMPERATURE, OXYGEN
//! for PHEHT select from: TEMPERATURE, PH, REDOX
//! for C4E select from: TEMPERATURE, CONDUCTIVITY
//! for NTU select from: TEMPERATURE, NTU_TURBIDITY
//! for CTZN select from: TEMPERATURE, CONDUCTIVITY
//! for MES5 select from: TEMPERATURE, SLUDGE_BLANKET, FAU_TURBIDITY
//!
//! Returns: 0 is OK, 1 if error
//!*************************************************************
response = mySensor.restoreToFactoryCalibration(TEMPERATURE);
if (response == 0)
{
USB.println(F("Restoring factory calibration OK"));
}
else
{
USB.println(F("Error restoring factory calibration of the sensor. \r\nCheck the sensor and restart the code."));
}
// 3. Turn off the sensor
mySensor.OFF();
}
void loop()
{
delay(5000);
}
Output
J#
Restoring factory calibration OK
---------------------------