- The battery has to be connected.
- This example can be executed in Waspmote v12
Code
/* * ------ [ZB_14] - set/get the power level -------- * * Explanation: This program shows how to set and read the power mode * at which the XBee module transmits at. Parameter Range: 0 - 4(default) * * XBee (S2) (boost mode enabled) * 0 = -8 dBm * 1 = -4 dBm * 2 = -2 dBm * 3 = 0 dBm * 4 = +2 dBm * ---------------------------------- * XBee-PRO (S2) * 4 = 17 dBm * ---------------------------------- * XBee-PRO (S2) - International variant - * 4 = 17 dBm * ---------------------------------- * XBee-PRO (S2B) (boost mode enabled) * 4 = 18 dBm * 3 = 16 dBm * 2 = 14 dBm * 1 = 12 dBm * 0 = 10 dBm * ---------------------------------- * XBee-PRO (S2B)- International variant - (boost mode enabled) * 4 = 10 dBm * 3 = 8 dBm * 2 = 6 dBm * 1 = 4 dBm * 0 = 2 dBm * ---------------------------------- * * REMARKS: Check your country's Restrictions * * Copyright (C) 2016 Libelium Comunicaciones Distribuidas S.L. * http://www.libelium.com * * This program is free software: you can redistribute it and/or modify * it under the terms of the GNU General Public License as published by * the Free Software Foundation, either version 3 of the License, or * (at your option) any later version. * * This program is distributed in the hope that it will be useful, * but WITHOUT ANY WARRANTY; without even the implied warranty of * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the * GNU General Public License for more details. * * You should have received a copy of the GNU General Public License * along with this program. If not, see . * * Version: 0.2 * Design: David Gascón * Implementation: Yuri Carmona */#include<WaspXBeeZB.h>// Define the power level value////////////////////////////////////////////////uint8_t powerValue=4;////////////////////////////////////////////////voidsetup(){ // Init USB portUSB.ON();USB.println(F("ZB_14 example\n")); USB.println(F("----------------------------------"));USB.println(F("\tPOWER LEVEL"));USB.println(F("----------------------------------\n""XBee (S2) (boost mode enabled)\n""0 = -8 dBm\n""1 = -4 dBm\n""2 = -2 dBm\n""3 = 0 dBm\n""4 = +2 dBm\n""----------------------------------\n""XBee-PRO (S2)\n""4 = 17 dBm\n""----------------------------------\n""XBee-PRO (S2) - International variant -\n""4 = 17 dBm\n""----------------------------------\n""XBee-PRO (S2B) (boost mode enabled)\n""4 = 18 dBm\n""3 = 16 dBm\n""2 = 14 dBm\n""1 = 12 dBm\n""0 = 10 dBm\n""----------------------------------\n""XBee-PRO (S2B)- International variant - (boost mode enabled)\n""4 = 10 dBm\n""3 = 8 dBm\n""2 = 6 dBm\n""1 = 4 dBm\n""0 = 2 dBm\n""----------------------------------\n""XBee-PRO (S2C)\n""4 = 5 dBm\n""3 = 3 dBm\n""2 = 1 dBm\n""1 = -1 dBm\n""0 = -5 dBm\n""----------------------------------\n""XBee-PRO (S2D)\n""4 = 18 dBm\n""3 = 16 dBm\n""2 = 14 dBm\n""1 = 12 dBm\n""0 = 0 dBm\n""----------------------------------"));delay(1000);// init XBeexbeeZB.ON();// get the Power LevelxbeeZB.getPowerLevel();USB.print(F("Current Power Level:"));USB.println(xbeeZB.powerLevel, DEC);USB.println();delay(1000);}voidloop(){ // 1. set the Power Level to powerValueUSB.print(F("Set the Power Level to "));USB.println(powerValue, DEC);xbeeZB.setPowerLevel(powerValue);// 2. get the Power LevelUSB.print(F("Read the Power Level:"));xbeeZB.getPowerLevel();USB.println(xbeeZB.powerLevel, DEC);USB.println();delay(1000);// 3. write actual value to moduleUSB.println(F("Write current value to module"));xbeeZB.writeValues();USB.println(F("******************************"));delay(10000);}
Output
E#
ZB_14 example
----------------------------------
POWER LEVEL
----------------------------------
XBee (S2) (boost mode enabled)
0 = -8 dBm
1 = -4 dBm
2 = -2 dBm
3 = 0 dBm
4 = +2 dBm
----------------------------------
XBee-PRO (S2)
4 = 17 dBm
----------------------------------
XBee-PRO (S2) - International variant -
4 = 17 dBm
----------------------------------
XBee-PRO (S2B) (boost mode enabled)
4 = 18 dBm
3 = 16 dBm
2 = 14 dBm
1 = 12 dBm
0 = 10 dBm
----------------------------------
XBee-PRO (S2B)- International variant - (boost mode enabled)
4 = 10 dBm
3 = 8 dBm
2 = 6 dBm
1 = 4 dBm
0 = 2 dBm
----------------------------------
Current Power Level:4
Set the Power Level to 4
Read the Power Level:4
Write actual value to module
******************************
...