Meshlium Technical Guide
Development website
rev202012
rev202012
  • Initial page
  • General and safety information
  • Important: read me before using
  • Meshlium v4.0 vs Meshlium v3.5
  • Contents of the box
  • Specifications
  • How to use Meshlium
  • Understanding Meshlium
  • Accessing Meshlium - make it easy!
  • Network interfaces setup
  • Wireless Sensor Networks
  • Meshlium Visualizer
  • Cloud Connectors
    • Premium Cloud Partners
      • Arrow
      • ElementBlue - RightSensor
      • Ericsson DDM
      • Libelium Cloud Bridge service
      • Telit
      • ThingWorx
    • Advanced Cloud Partners
      • Microsoft Azure Event Hubs
      • Microsoft Azure IoT Hub
      • Ensura
      • Infiswift
      • Ubicamovil
    • Basic Cloud Partners
      • Alibaba Cloud
      • Amazon IoT
      • Amplia's OpenGate
      • Arnaldo Castro
      • Aveva (Wonderware)
      • BaseN
      • Biz4Intellia
      • B-Scada
      • C2M
      • ConsulMedia
      • Cumulocity
      • DeviceLynk
      • eagle.io
      • Esri
      • Extunda
      • Fujitsu IoT Connector
      • HaibuSmart
      • IBM Cloud
      • IoT-Ticket
      • IoTSens
      • Kii
      • Labeeb
      • Maxvec
      • MQTT
      • NEC Connexive
      • Orchestra
      • Redd
      • RIOT Platform
      • RoboMQ
      • scriptr.io
      • SensorUp IoT Platform
      • Sentilo
      • Simfony
      • SmartCityPlatform
      • SmartDataSystem (powered by Sentilo)
      • SmartPlants
      • Sofia2
      • Sparkcompass
      • Sparkster
      • TechEdge SAP HANA
      • Telefonica IoT Platform
      • ThingPlus
      • ThingSpeak
  • Device Connectors
  • Smartphone detection
  • Tools
  • Database management
  • System Information
  • Upgrading Meshlium
  • Rescue System
  • Manager System changelog
  • Documentation changelog
  • Certifications
  • Maintenance
  • Disposal and recycling
Powered by GitBook
On this page
  • Arrow Connect IoT Cloud Platform
  • Register Meshlium in Arrow Connect
  • Configuration
  • Controlling synchronization

Was this helpful?

  1. Cloud Connectors
  2. Premium Cloud Partners

Arrow

PreviousPremium Cloud PartnersNextElementBlue - RightSensor

Last updated 4 years ago

Was this helpful?

Arrow Connect IoT Cloud Platform

Arrow Connect is a software solution that plumbs the data from the edge to the cloud. Developed by Arrow Electronics and designed with security, scale, flexibility, device management, open APIs and extensibility as core tenants enabling broad use cases across multiple industries. You can provision, control, import, assign, activate, update, suspend, replace, deactivate, and more, all from a single platform. Arrow Connect makes device management easy so you can focus on driving business value via data analytics and machine learning tools.

Visit for more information.

Register Meshlium in Arrow Connect

To request for a developer account in Arrow Connect platform, follow the Developer Registration process on or please email to including the following information:

  • Company name.

  • Full name.

  • Title.

  • Email address.

  • How did you hear about us?

  • Short description of your project.

Log on to the portal at using your developer account.

With the developer account, you have a private application instance with full admin access. Upon logging in, click on Administration > Access Keys, then click on the Master Key. You can save the "Client Encrypted API Key" and "Client Encrypted Secret Key" to the notepad. This pair of keys will be used to configure the Meshlium to connect to your cloud account.

Configuration

Paste the keys above into the 2 text areas as screen-shot below.

All the default configuration values should be appropriate and you do not need to change them. Click on the "Save" button for storing the configuration fields.

  • API URL.

  • MQTT URL.

  • Encrypted API Key.

  • Encrypted Secret Key.

After clicking the "Save" button, you also need to click on "Reset Local Database", otherwise your changes will not be affected.

In all cases, to prevent local database corruption, the configuration should never be updated while the Arrow Connect IoT Cloud Connector is running. Use the Start/Stop buttons as described below to stop it before making changes, restart it after saving changes.

Controlling synchronization

Launch the Meshlium Arrow Connect IoT Cloud background process (Start button). The program will search for the received frames on the local database, and will send them to the Arrow Connect IoT Cloud Platform. The status indicator displays the current state. Green colour means running.

Stop the Arrow Connect program anytime by clicking on the "Stop" button. Red colour means stopped.

While the program is running, log on to the Arrow Connect portal to check that the Meshlium and Waspmotes have been properly registered and are sending telemetry data. See some example screen-shots below:

http://iot.arrow.com/developer.html
https://portal.arrowconnect.io/#/signup
tnguyen@arrow.com
https://portal.arrowconnect.io
Figure : Arrow portal
Figure : Access Key
Figure : Configure Arrow
Figure : Synchronization stopped
Figure : Synchronization running
Figure : Arrow gateways display
Figure : Arrow Meshlium display
Figure : Arrow Waspmote display