Models
Last updated
Last updated
There are some defined configurations of Waspmote Plug & Sense! depending on which sensors are going to be used. Waspmote Plug & Sense! configurations allow to connect up to six sensor probes at the same time.
Each model takes a different conditioning circuit to enable the sensor integration. For this reason, each model allows connecting just its specific sensors.
This section describes each model configuration in detail, showing the sensors which can be used in each case and how to connect them to Waspmote. In many cases, the sensor sockets accept the connection of more than one sensor probe. See the compatibility table for each model configuration to choose the best probe combination for the application.
It is very important to remark that each socket is designed only for one specific sensor, so they are not interchangeable. Always be sure you have connected the probes in the right socket. Otherwise, they can be damaged.
In the next table we show the sensor board which corresponds to each Plug & Sense! model:
The Smart Environment PRO model has been created as an evolution of Smart Environment. It enables the user to implement pollution, air quality, industrial, environmental or farming projects with high requirements in terms of high accuracy, reliability and measurement range as the sensors come calibrated from factory.
Sensor sockets are configured as shown in the table below:
For more technical information about each sensor probe, go to the Gases PRO Sensor Guide: https://development.libelium.com/gases_pro_sensor_guide/
Calibrated gas sensors are manufactured once the order has been placed to ensure maximum durability of the calibration feature. The manufacturing process and delivery may take from 4 to 6 weeks. The lifetime of calibrated gas sensors is 6 months working at maximum accuracy. We strongly encourage our customers to buy extra gas sensors to replace the original ones after that time to ensure maximum accuracy and performance.
The main applications for this Waspmote Plug & Sense! configuration are perimeter access control, liquid presence detection and doors and windows openings. Besides, a relay system allows this model to interact with external electrical machines.
The probes attached in this photo could not match the final location. See next table for the correct configuration.
As we see in the figure below, thanks to the directional probe, the presence sensor probe (PIR) may be placed in different positions. The sensor can be focused directly to the point we want.
For more technical information about each sensor probe, go to the Events Sensor Guide: https://development.libelium.com/events-sensor-guide/
The Smart Water model has been conceived to facilitate the remote monitoring of the most relevant parameters related to water quality. With this platform you can measure more than 5 parameters, including the most relevant for water control such as dissolved oxygen, oxidation-reduction potential, pH, conductivity and temperature.
The Smart Water Ions line is complementary for these kinds of projects, enabling the control of concentration of ions like Ammonium (NH 4+ ), Bromide (Br - ), Calcium (Ca 2+ ), Chloride (Cl - ), Cupric (Cu 2+ ), Fluoride (F - ), Iodide (I - ), Lithium (Li + ), Magnesium (Mg 2+ ), Nitrate (NO 3- ), Nitrite (NO 2- ), Perchlorate (ClO 4- ), Potassium (K + ), Silver (Ag + ), Sodium (Na + ) and pH. Take a look to the Smart Water Ions line in the next section.
Sensor sockets are configured as shown in the table below:
For more technical information about each sensor probe, go to the Smart Water Sensor Guide: https://development.libelium.com/smart_water_sensor_guide/
Smart Water Xtreme was created as an evolution of Smart Water. This model integrates high-end sensors, calibrated in factory, with enhanced accuracy and performance. Their reduced recalibration requirements and robust design enlarge maintenance periods, making it more affordable to deploy remote Smart Water applications. This line includes a great combination of the most significant water parameters like dissolved oxygen, pH, oxidation-reduction potential, conductivity, salinity, turbidity, suspended solids, sludge blanket and temperature.
Sensor sockets are configured as shown in the table below:
For more technical information about each sensor probe, go to the Smart Water Xtreme Sensor Guide: https://development.libelium.com/smart-water-xtreme-sensor-guide/
The Smart Water Ions model specializes in the measurement of ions concentration for drinking water quality control, agriculture water monitoring, swimming pools or waste water treatment. The PRO sensors have higher performance than the former Single and Double sensors.
The Smart Water line is complementary for these kinds of projects, enabling the control of parameters like conductivity, oxidation-reduction potential and dissolved oxygen. Take a look to the Smart Water line in the previous section.
This special variant integrates extreme quality sensors, with better performance than the Single or Double lines. In this case, there is only one type of reference probe and up to 16 different ion parameters can be analyzed in 4 sockets. Sensor sockets are configured as shown in the table below:
For more technical information about each sensor probe, go to the Smart Water Ions Sensor Guide: https://development.libelium.com/smart-water-ions-sensor-guide/
The Smart Agriculture models allow to monitor multiple environmental parameters involving a wide range of applications. It has been provided with sensors for air and soil temperature and humidity, solar visible radiation, wind speed and direction, rainfall, atmospheric pressure, etc.
The main applications for this Waspmote Plug & Sense! model are precision agriculture, irrigation systems, greenhouses, weather stations, etc.
Sensor sockets are configured as shown in the table below:
*Ask Libelium Sales Department for more information.
For more technical information about each sensor probe, go to the Smart Agriculture Sensor Guide: https://development.libelium.com/agriculture-sensor-guide/
The Plug & Sense! Smart Agriculture Xtreme is an evolution of our Agriculture line with a new selection of high-end professional sensors. It allows to monitor multiple environmental parameters involving a wide range of applications, from plant growing analysis to weather observation. There are sensors for atmospheric and soil monitoring and plants health. 20+ sensors can be connected.
Sensor sockets are configured as shown in the table below:
For more technical information about each sensor probe, go to the Smart Agriculture Xtreme Sensor Guide: https://development.libelium.com/smart-agriculture-xtreme-sensor-guide/
This model is designed to monitor the main environment parameters easily. Only 3 sensor probes are allowed for this model, as shown in next table.
Sensor sockets are configured as it is shown in table below:
As we see in the figure below, thanks to the directional probe, the Luminosity (Luxes accuracy) sensor probe may be placed in different positions. The sensor can be focused directly to the light source we want to measure.
For more technical information about each sensor probe, go to the Events Sensor Guide: https://development.libelium.com/events-sensor-guide/
The main applications for this Waspmote Plug & Sense! model are noise maps (monitor in real time the acoustic levels in the streets of a city), air quality, waste management, smart lighting, etc.
Sensor sockets are configured as shown in the table below:
For more technical information about each sensor probe, go to the Smart Cities PRO Sensor Guide: https://development.libelium.com/smart-cities-pro-sensor-guide/
Calibrated gas sensors are manufactured once the order has been placed to ensure maximum durability of the calibration feature. The manufacturing process and delivery may take from 4 to 6 weeks. The lifetime of calibrated gas sensors is 6 months working at maximum accuracy. We strongly encourage our customers to buy extra gas sensors to replace the original ones after that time to ensure maximum accuracy and performance.
The applications for this Plug & Sense! model are focused on adding wireless connectivity to 4-20 mA devices and connecting them to the Cloud.
Sensor sockets are configured as shown in the table below:
For more technical information, go to the 4-20 mA Sensor Guide: https://development.libelium.com/4-20-ma-sensor-guide/
With the most popular Industrial Protocols integrated in a single device (Modbus, RS-485, RS-232, 4-20 mA, SDI-12), this model allows the connection of any sensor or actuator among 1,000s on the market. Besides, Libelium offers extreme flexibility (open source API and IDE) and top inter-operability, so factories can enter the Industry 4.0 era.
Sensor sockets are configured as shown in the table below:
For more technical information, go to the Industry 4.0 Sensor Guide: https://development.libelium.com/industry-4-0-sensor-guide/
Plug & Sense! model
Equivalent Waspmote OEM sensor board
Plug & Sense! Smart Environment PRO
Gases PRO Sensor Board
Plug & Sense! Smart Agriculture PRO
Smart Agriculture PRO Sensor Board
Plug & Sense! Smart Agriculture Xtreme
Smart Agriculture Xtreme Sensor Board (not on sale)
Plug & Sense! Smart Water
Smart Water Sensor Board
Plug & Sense! Smart Water Xtreme
Smart Water Xtreme Sensor Board (not on sale)
Plug & Sense! Smart Water Ions
Smart Water Ions Sensor Board
Plug & Sense! Smart Cities PRO
Smart Cities PRO Sensor Board
Plug & Sense! Ambient Control
No sensor board inside (direct connection of sensor wires to Waspmote)
Plug & Sense! Smart Security
Events Sensor Board
Plug & Sense! 4-20 mA Current Loop
4-20 mA Current Loop Sensor Board
Sensor socket
Parameter
Reference
A, B, C or F
Carbon Monoxide (CO) for low concentrations [Calibrated]
9371-LC-P
A, B, C or F
Carbon Dioxide (CO2 ) [Calibrated]
9372-P
A, B, C or F
Oxygen (O2 ) [Calibrated]
9373-P
A, B, C or F
Ozone (O3 ) [Calibrated]
9374-P
A, B, C or F
Nitric Oxide (NO) for low concentrations [Calibrated]
9375-LC-P
A, B, C or F
Nitric Dioxide (NO2 ) high accuracy [Calibrated]
9376-HA-P
A, B, C or F
Sulfur Dioxide (SO2 ) high accuracy [Calibrated]
9377-HA-P
A, B, C or F
Ammonia (NH3 ) for low concentrations [Calibrated]
9378-LC-P
A, B, C or F
Ammonia (NH3 ) for high concentrations [Calibrated]
9378-HC-P
A, B, C or F
Methane (CH4 ) and Combustible Gas [Calibrated]
9379-P
A, B, C or F
Hydrogen Sulfide (H2S) [Calibrated]
9381-P
D
Particle Matter (PM1 / PM2.5 / PM10) - Dust
9387-P
E
Temperature, humidity and pressure
9370-P
E
Luminosity (Luxes accuracy)
9325-P
E
Ultrasound (distance measurement)
9246-P
Sensor socket
Parameter
Reference
A, C, D or E
Temperature + Humidity + Pressure
9370-P
A, C, D or E
Luminosity (Luxes accuracy)
9325-P
A, C, D or E
Ultrasound (distance measurement)
9246-P
A, C, D or E
Presence - PIR
9212-P
A, C, D or E
Liquid Level (combustible, water)
9239-P, 9240-P
A, C, D or E
Liquid Presence (Point, Line)
9243-P, 9295-P
A, C, D or E
Hall Effect
9207-P
B
Liquid Flow (small, medium)
9296-P, 9297-P
F
Relay Input-Output
9270-P
Sensor socket
Parameter
Reference
A
pH
9328
B
Dissolved Oxygen (DO)
9327
C
Conductivity
9326
E
Oxidation-Reduction Potential (ORP)
9329
F
Soil/Water Temperature
9255-P (included by default)
Sensor socket
Parameter
Reference
A, B, C, D and E
Optical dissolved oxygen and temperature OPTOD
9488-P
A, B, C, D and E
Titanium optical dissolved oxygen and temperature OPTOD
9489-P
A, B, C, D and E
pH, ORP and temperature PHEHT
9485-P
A, B, C, D and E
Conductivity, salinity and temperature C4E
9486-P
A, B, C, D and E
Inductive conductivity, salinity and temperature CTZN
9487-P
A, B, C, D and E
Turbidity and temperature NTU
9353-P
A, B, C, D and E
Suspended solids, turbidity, sludge blanket and temperature MES5
9490-P
A, B, C, D and E
COD, BOD, TOC, SAC254 and temp StacSense, 2 mm path
9500-P
A, B, C, D and E
COD, BOD, TOC, SAC254 and temp StacSense, 50 mm path
9501-P
A, B, C and D
Radar level VEGAPULS C21
9514-P
A and D
Temperature, air humidity and pressure
9370-P
A and D
Luxes
9325-P
A and D
Ultrasound
9246-P
F
Total coliform bacteria, TLF, turbidity and temperature Proteus
9513-P
F
Manta+ 35A sensor probe
9495-P
F
Manta+ 35B sensor probe
F
Chlorophyll sensor for Manta probe
72470
F
BGA sensor for Manta probe
72471
F
Organic matter CDOM/FDOM sensor for Manta probe
72472
F
Ammonium sensor for Manta probe
72473
F
Nitrate sensor for Manta probe
72474
F
Chloride sensor for Manta probe
72475
F
Sodium sensor for Manta probe
72476
F
Calcium sensor for Manta probe
72477
F
Bromide sensor for Manta probe
9504-P
F
Total Dissolved Gas TDG sensor for Manta probe
9505-P
F
Rhodamine sensor for Manta probe
9506-P
F
Crude oil sensor for Manta probe
9507-P
F
Refined oil sensor for Manta probe
9508-P
F
Flourescein sensor for Manta probe
9509-P
F
Optical brighteners sensor for Manta probe
9510-P
F
Tryptophan sensor for Manta probe
9511-P
Sensor socket
Parameter
Reference
A, B, C or D
Ammonium Ion (NH 4+ ) [PRO]
9412
A, B, C or D
Bromide Ion (Br ) [PRO]
9413
A, B, C or D
Calcium Ion (Ca 2+) [PRO]
9414
A, B, C or D
Chloride Ion (Cl - ) [PRO]
9415
A, B, C or D
Cupric Ion (Cu 2+ ) [PRO]
9416
A, B, C or D
Fluoride Ion (F ) [PRO]
9417
A, B, C or D
Iodide Ion (I ) [PRO]
9418
A, B, C or D
Lithium Ion (Li + ) [PRO]
9419
A, B, C or D
Magnesium Ion (Mg 2+ ) [PRO]
9420
A, B, C or D
Nitrate Ion (NO 3- ) [PRO]
9421
A, B, C or D
Nitrite Ion (NO 2- ) [PRO]
9422
A, B, C or D
Perchlorate Ion (ClO 4- ) [PRO]
9423
A, B, C or D
Potassium Ion (K + ) [PRO]
9424
A, B, C or D
Silver Ion (Ag+ ) [PRO]
9425
A, B, C or D
Sodium Ion (Na+ ) [PRO]
9426
A, B, C or D
pH [PRO]
9411
E
Reference Sensor Probe [PRO]
9410 (included by default)
F
Soil/Water Temperature
9255-P (included by default)
Sensor socket
Parameter
Reference
A
Weather Station WS-3000 (anemometer + wind vane + pluviometer)
9256-P
B
Soil Moisture 1
9248-P, 9324-P, 9323-P
B
Solar Radiation (PAR)
9251-P
B
Ultraviolet Radiation
9257-P
C
Dendrometers
9248-P, 9324-P, 9323-P
C
Dendrometers
9252-P, 9253-P, 9254-P
D (digital bus)
Soil Temperature (Pt-1000)
9255-P
D (digital bus)
Temperature + Humidity + Pressure
9370-P
D (digital bus)
Luminosity (Luxes accuracy)
9325-P
D (digital bus)
Ultrasound (distance measurement)
9246-P
E
Leaf Wetness
9249-P
E
Soil Moisture 2
9248-P, 9324-P, 9323-P
F (digital bus)
Temperature + Humidity + Pressure
9370-P
F (digital bus)
Luminosity (Luxes accuracy)
9325-P
F (digital bus)
Ultrasound (distance measurement)
9246-P
Sensor socket
Parameter
Reference
A and D
Non-contact surface temperature measurement SI-411
9468-P
A and D
Leaf and flower bud temperature SF-421
9467-P
A and D
Soil oxygen level SO-411
9469-P
A and D
Volumetric water content and soil temperature TEROS 11
9512-P
A and D
Conductivity, water content and soil temperature TEROS 12
9499-P
A and D
Soil water potential TEROS 21
9465-P
A and D
Vapor pressure, humidity, temperature and air pressure sensor probe (ATMOS 14)
9471-P
A and D
Temperature, air humidity and pressure
9370-P
A and D
Luxes
9325-P
A and D
Ultrasound
9246-P
B
Non-contact surface temperature measurement SI-411
9468-P
B
Leaf and flower bud temperature SF-421
9467-P
B
Soil oxygen level SO-411
9469-P
B
Volumetric water content and soil temperature TEROS 11
9512-P
B
Conductivity, water content and soil temperature TEROS 12
9499-P
B
Soil water potential TEROS 21
9465-P
B
Vapor pressure, humidity, temperature and air pressure sensor probe (ATMOS 14)
9471-P
B
Leaf wetness Phytos 31
9466-P
B
Shortwave radiation SP-510
9470-P
B
Solar radiation (PAR) SQ-110 for Smart Agriculture Xtreme
9251-PX
B
Ultraviolet radiation SU-100 for Smart Agriculture Xtreme
9257-PX
B
4-20 mA type (generic)
-
C
Non-contact surface temperature measurement SI-411
9468-P
C
Leaf and flower bud temperature SF-421
9467-P
C
Soil oxygen level SO-411
9469-P
C
Volumetric water content and soil temperature TEROS 11
9512-P
C
Conductivity, water content and soil temperature TEROS 12
9499-P
C
Soil water potential TEROS 21
9465-P
C
Vapor pressure, humidity, temperature and air pressure sensor probe (ATMOS 14)
9471-P
C
Dendrometers (DC3, DD-S, DF) for Smart Agriculture Xtreme
9252-PX, 9253-PX, 9254-PX
C
Shortwave radiation SP-510
9470-P
C
Solar radiation (PAR) SQ-110 for Smart Agriculture Xtreme
9251-PX
C
Ultraviolet radiation SU-100 for Smart Agriculture Xtreme
9257-PX
E
Shortwave radiation SP-510
9470-P
E
Solar radiation (PAR) SQ-110 for Smart Agriculture Xtreme
9251-PX
E
Ultraviolet radiation SU-100 for Smart Agriculture Xtreme
9257-PX
E
Weather station GMX-240 (W-PO)
E
Weather station GMX-541 (W-PO-T-H-AP-R)
9481-P
E
Weather station GMX-600 (W-PO-T-H-AP)
9484-P
E
Solar radiation and temperature Datasol MET probe
9496-P
F
Shortwave radiation SP-510
9470-P
F
Solar radiation (PAR) SQ-110 for Smart Agriculture Xtreme
9251-PX
F
Ultraviolet radiation SU-100 for Smart Agriculture Xtreme
9257-PX
F
RS-232 type (generic)
-
F-
4-20 mA type (generic)
-
Sensor socket
Parameter
Reference
A
Temperature + Humidity + Pressure
9370-P
B
Luminosity (LDR)
9205-P
C
Luminosity (Luxes accuracy)
9325-P
D, E and F
Not used
-
Sensor socket
Parameter
Reference
A
Noise level sensor
NLS
A
Temperature + Humidity + Pressure
9370-P
A
Luminosity (Luxes accuracy)
9325-P
A
Ultrasound (distance measurement)
9246-P
B, C, and F
Carbon Monoxide (CO) for low concentrations [Calibrated]
9371-LC-P
B, C, and F
Carbon Dioxide (CO2 ) [Calibrated]
9372-P
B, C, and F
Oxygen (O2 ) [Calibrated]
9373-P
B, C, and F
Ozone (O3 ) [Calibrated]
9374-P
B, C, and F
Nitric Oxide (NO) for low concentrations [Calibrated]
9375-LC-P
B, C, and F
Nitric Dioxide (NO2 ) high accuracy [Calibrated]
9376-HA-P
B, C, and F
Sulfur Dioxide (SO2 ) high accuracy [Calibrated]
9377-HA-P
B, C, and F
Ammonia (NH3 ) for low concentrations [Calibrated]
9378-LC-P
B, C, and F
Ammonia (NH3 ) for high concentrations [Calibrated]
9378-HC-P
B, C, and F
Methane (CH4 ) and Combustible Gas [Calibrated]
9379-P
B, C, and F
Hydrogen Sulfide (H2S) [Calibrated]
9381-P
B, C, and F
Hydrogen Chloride (HCl) [Calibrated]
9382-P
B, C, and F
Temperature + Humidity + Pressure
9370-P
B, C, and F
Luminosity (Luxes accuracy)
9325-P
B, C, and F
Ultrasound (distance measurement)
9246-P
D
Particle Matter (PM1 / PM2.5 / PM10) - Dust
9387-P
E
Temperature + Humidity + Pressure
9370-P
E
Luminosity (Luxes accuracy)
9325-P
E
Ultrasound (distance measurement)
9246-P
Sensor socket
Board channel
Reference
A
Channel 1 (type 2 and type 3)
9270-P
B
Channel 2 (type 2 and type 3)
9270-P
C
Channel 3 (type 2 and type 3)
9270-P
D
Channel 4 (type 4)
9270-P
Sensor socket
Protocol
A
SDI-12
B
SDI-12 / 4-20 mA
C
SDI-12
D
SDI-12
E
RS-485 / Modbus
F
RS-232 / Modbus / 4-20 mA